                         NOTE: Any fluctuation of the voltmeter needle. The amount the needle
                         fluctuates indicates the voltage leak through the condenser. If the leak
                         exceeds 10 volts the condenser is faulty and should be replaced by another.
                         If, however, the leak does not exceed 10 volts, disconnect the power circuit
                         leads from the condenser and short circuit the condenser lead on to the
                         body. A powerful discharge should result. This is indicated by a spark, if no
                         spark or a very weak spark is evident the condenser is faulty as it will not
                         hold a charge for a short period.























































                  FIGURE 33. DELCO REMY AUTOMATIC ADVANCE MECHANISM


                         COIL


         SECTION         Three types of ignition coil have been fitted, but only the latest type 12 volt
            535          coil is serviced.

                         The first and second type are 6 volt coils, and a resistance unit is fitted in
                         the ignition circuit. With the first type of coil the resistance unit is fitted
                         on the side of the distributor body, and with the second type it is attached
                         to the coil. No resistance is necessary in the ignition circuit with the latest