Specifications                                                                           Issue No. 1 CE

Voltage      Ranges (Auto or Manual)                0.5V to 2000Vpk
(V)          (12 ranges 1 - 2 - 5 sequence)         (1400V rms)

Current      Scaling Factors.                       0.001 to 99999
(A)
             Computation                            True rms or rectified mean

             Crest Factor                           Up to 20

             Frequency Range                        DC and 0.1Hz to 500kHz

             Accuracy (23°C ± 5°C; DC and 45 to 450Hz ± 0.05% reading±0.05% range±20mV
             0.2V to 1000V rms) 0.5Hz to 500kHz ± 0.1% reading ± 0.05% range

                                                                ± 0.02%/kHz ± 20mV

             Effect of Common   1000V rms at 60Hz Less than 20mV
             Mode Voltage       100V rms at 100kHz Less than 1V

             Maximum Input      Continuous          1500Vpk
                                1 Second            5000Vpk

             Input Impedance                        1MΩ and 100pF on all ranges

             Ranges (Auto or Manual)                INT 0.05A to 200Apk (30A rms)
             (12 ranges 1 - 2 - 5 sequences)        EXT 6.25mV to 2.5Vpk (1.5Vrms)

             Scaling Factor                         INT 0.00001 to 99999
                                                    EXT 0.8μA/mV to 8000A/mV

             Computation                            True rms or rectified mean

             Crest Factor                           Up to 20

             Frequency Range                        DC and 0.1Hz to 500kHz

             Accuracy (23° ± 5°C; 45Hz to 450Hz     ± 0.05% reading ± 0.05% range ± 1mA

             80mA to 30A rms)   0.5Hz to 500kHz ± 0.1% reading ± 0.05% range ± 0.08%/kHz ± 1mA

                                DC: ± 0.05% reading ± 0.05% range ± 9mA*

             Effects of Common  1000V rms at 60Hz Less than 2mA
             Mode Voltage       100V rms at 100kHz Less than 50mA
             Maximum
             Input              Continuous          30A rms (must be limited by external fuses or CT's)

             Input Impedance    1 Second                  1000Apk
                                                    INT 0.0035Ω on all ranges

                                                    EXT 20kΩ in parallel with 10pF on all ranges

Power (W)    Ranges (Auto or Manual)                25mW to 400kW pk (with scaling to 100,000MW)
**           (144 ranges corresponding to V and A)
                                                    DC and 0.1Hz to 500kHz
             Frequency Range                        ± Arms x δV ± Vrms x δA ± (0.06/PF) % ± 1mW
                                                    ± Arms x δV ± Vrms x δA ± (0.1/PF) % ± 1mW
             Accuracy (23° ± 5°C, 45Hz to 450Hz

             sinewave)          0.5Hz to 500kHz

             Polarity                               + indicates positive power flow
                                                    - indicates negative power flow
Apparant     Ranges (Auto or Manual)
Power (VA)   (144 ranges corresponding to V and A)  25mVA to 400kVA pk (with scaling to 100,000MVA)

**           Frequency Range                        DC and 0.5Hz to 500kHz
                                                    ± Arms x δV ± Vrms x δA ± (0.06/PF) % ± 1mVA
             Accuracy (23° ± 5°C, 45Hz to 450Hz     ± Arms x δV ± Vrms x δA ± (0.1/PF) % ± 1mVA

             sinewave)          0.5Hz to 500kHz

Reactive     Ranges (Auto or Manual)                25mVAr to 400kVAr pk (with scaling to 100,000MVAr)
Power (VAr)  (144 ranges corresponding to V and A)
                                                    0.5Hz to 500kHz
**           Frequence Range                        ± Arms x δV ± Vrms x δA ± [0.06/(1-PF2)0.5] ±1mVAr
                                                    ± Arms x δV ± Vrms x δA ± [0.1/(1-PF2)0.5] % ± 1mVAr)
             Accuracy (23° ± 5°C, 45Hz to 450Hz

             sinewave)          0.5Hz to 500kHz

             Polarity                               + indicates inductive load
                                                    - indicates capacitive load

* Specification using auto-zero. User may also perform a manual zero to cancel offset.                     17
** δ = Deviation: ie. δV = Voltage Deviation